Remote electrical control of narrow stile aluminum doors (7160) or hollow metal/wood doors (7170) equipped with a mortise or cylindrical lockset with up to 3/4" [19.1 mm] latchbolt projection without deadbolt. Electrical actuation unlocks the keeper, releasing the latchbolt so the door may be opened without operating the latch itself. The electric strike must be positioned to accommodate offset mortise latches during installation. Please refer to installation instructions or contact factory for more information.
UL 1034 burglary-resistant listed
UL 294 (6th Edition) listed
Case: 1" x 3-3/8" x 1-7/8" deep [25.4 mm x 85.7 mm x 47.6 mm].
Strike Opening: Bolt retaining keeper is stainless steel. Strike location must be centered on latchbolt.
7160: 3/4" x 1-7/16" x 5/8" deep [19.1 mm x 36.5 mm x 15.9 mm deep].
7170: 5/8" x 1-7/16" x 5/8" deep[15.9 mm x 36.5 mm x 15.9 mm deep].
Strike Lip: Basic strike has lip of proper length for 1-3/4" [44.5 mm] thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number.
Latchbolt Projection: 3/4" [19.1 mm]
Faceplate: 1-1/4" x 4-7/8" [31.8 mm x 123.8 mm]. Available in a variety of architectural finishes.
7160: Flat with radius corners
7170: Flat with square corners
Standard Package: Individually boxed with mounting screws.
7160 includes mounting clips, adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8" [3.2 mm].
7170 includes mounting clips and adhesive shims for use when welded tabs are omitted.
Shipping weight: 2 lbs [0.91 kg].
Voltage: Available in 12, 16, or 24 Volt AC and DC. DC continuous units are silent, AC intermittent units “buzz” on operation.
Current Draw:
0.33A at 12 VDC, 1.42A at 12 VAC
0.22A at 16 VDC, 0.63A at 16 VAC
0.17A at 24 VDC, 0.74A at 24 VAC
Fail Safe | Fail Secure: Field selectable at time of installation. However, AC intermittent solenoid must not be used continuously in either.
• Available with two Form ‘C’ monitoring switches to indicate when the latchbolt is engaged in the strike and whether the strike jaw is blocked.
• Lip extension kits for various dimensions of door centerline to jamb edge.
• Modular Packaging: Match one strike body kit with one faceplate kit to make a complete electric strike. Faceplate kits contain all hardware to mount electric strike. Please contact factory or sales representative for details.
Product Note: All 3/4" throw latches require 1/8" minimum door gap. Horizontal center line of strike must match line of mortise latchbolt.
Related Products: When purchasing this product, please consider the following related products, available separately:
Options & Accessories | Power |
Lip Extension Kits, Modular Kits, Monitor Kits |
4603 Rectifier, 4605/4606 Transformer, Piezo Horn audible indicator, ElectroLynx connector |